|
Please:
- Do not edit or alter the 'info' file - it is
processed automatically after verification.
- All requests not submitted by the Contact Person may be discarded by our automatic system.
- Note that the access_prod program does not
work properly if the set-up of the computer operating system is not consistent.
The most common problems are discussed
here.
License key file, cr_info, needs to be present in the /usr/local/lib directory in order for the
HKL/HKL-2000 programs to run. One cr_info file may contain information about many
computers and detectors. The program looks through the cr_info file for the right
combination of fields that matches the given detector family and computer information,
other fields are ignored.
The cr_info file will look like the following:
|
`~:Ddj@Qsw0fOouyHhnrwyadij@)WxBde46kM$PRSYdIORW468rxdeJL)=+[cemr
uvbjl$T-_efOP)v+gLQqrV=CFHJntzD4jpvaiRsaEFkop*a5H^+]59$Stw16pR-2
IKNRvdf5k^_WAGLM$O=1EGOopuY]EIn(0f!$&uc3iqu=2l^QYdi$Pr)]e6#oprA1
CcHmpsXCch@%=4j$%PrTucHN_z0cdHLms(uvxb5Kos(XB27qu]efjl@OPT1G9Lm$
^t)Wy01fJKLNs([EKLTY23hl@nWEJjrA4JO*-d7!PucG%^r=4gKmV3GOTxC3hJOq
(xBbe9M$&RTy3GIjLOq&sX08L%-X1ksXF6kl#-Af!P&R]b6kPXFJlPuv+z]7q_Xy
Dij9!^-XDiMSxGIOt_+zBJlt[c67JlU25@nRWwB5klqt)xzDJ!LPSWZDdMrW+13I
kpstXDf!tzD78rADGk^Qu[24Ffn$^-XYa02gjLl@)_ag@nqw16!LMm%RUZeN%xZ7
KPuYck@q()WAIQY6kM$)W]e8#$SX06i8@*]4Jl&vwcH@MoQRXF$&uvwxBDfijnp)
=19suxCD@#qZE8#%*T1klNOQqrtX1f5!$%x[DL#%*+glN&RWXDh9LOs)1gjp)WCI
#PSTtwa2!Nnq-Aae9^)Vx15GM^)xdejoruwacfintV[013mR_AEM^_19Lptwyglp
vXc4!@n%x[6kn(b3E7^Swa1CD@uYAbDEgjntVvaCcfKORs=y[4ijrwbgk%RW]5$r
sXYE89MN%Ptuvy0jmR_Ydjl&SV37KM&za2EFGgLp*]FNPVXcHJOTZF9nWCIJkoST
yeksUw06MnWxbg8nSuweh7jO=2FLmV]B24FLOR_zc:
|
To obtain the license key, you need to run the access_prod
program on each machine that you plan to use for running any of the HKL programs.
Executing the access_prod results in the following dialog (answers in red, comments in italic):
enter the name of your institution: State University
enter the name of PI: John Doe (Principal
Investigator or Group Leader)
enter the name of person responsible for HKL maintenance: Jane Doe
enter names of all frame formats (detectors) you want to use: mar raxis4 (see below)
enter the number of detectors in your lab which are
currently supported by HKL package: 2
enter the name of company from which you received
your license: HKL Research, Inc. (Other
Possible Software Providers: MSC, Nonius, MARresearch)
enter HKL version number: 1.97.2
if this is temporary license, enter the number of days you request,
for permanent license enter 'noexpir': noexpir
do you want to send automatically e-mail to hkl@hkl-xray.com
in order to activate your license (y) ? n
If the answer is y (yes), the access_prod program may automatically send an e-mail with a request
for an access file: cr_info. It not always works, though. If the answer is n (no) the program will produce the following info file.
You may save the info file and afterwards 'manually' send it to hkl@hkl-xray.com.
The example of an 'info' file created by the access_prod program is given below (comments in italic) :
|
HOST-NAME: vp4.med.state.edu |
|
(extracted by the program - do not
edit!) NOTE: the field is limited in length to 30 characters |
|
HOST-ID: -2035379618 |
|
(extracted by the program - do not
edit!) |
|
HOSTNAME: state.edu |
|
(extracted by the program - do not
edit!) |
|
HW_PROV: sgi |
|
(extracted by the program - do not
edit!) |
|
CPU-SERIAL: sgi,CPU,1762854231 |
|
(extracted by the program - do not
edit!) |
|
INSTITUTION: State University |
|
Licensee's Institution name |
|
PI: John Doe |
|
Principal Investigator or Group Leader |
|
CONTACT: Jane Doe |
|
Contact Person |
|
DETECTORS: mar raxis4 |
|
Detector Families |
|
NO-OF-DET: 2 |
|
Number of Detectors at Home Laboratory |
|
PROVIDER: HKL Research, Inc. |
|
License Provider: MSC, HKL, etc. |
|
VERSION: 1.97.2 |
|
Requested Version of the Program |
|
EXPIR: noexpir |
|
example: 60, Jan 1 2007 |
The following are detector families to be used in the above
'questionnaire':
- dip - DIP family of scanners
- raxis2 - RAXIS-II
- raxis4 - RAXIS-IV
- raxis5 - RAXIS-V
- mar - MAR imaging plate detectors (except MAR345)
- mar345 - MAR345 detector
- brandeis - Brandeis 1k CCD detector on line X12c at BNL
- unsup - ADSC Quantum-4 CCD detector
- unsup210 - ADSC Quantum-210 detector
- unsup315- ADSC Quantum-315 detector
- un-mar - MAR CCD detector 130mm
- un-mar165 - MAR CCD detector 165mm
- un-brand - CCD
Brandeis 2x2
You should get the cr_info file from us by return mail. Usually it should take no more than 48h to receive cr_info. The cr_info file should be
placed in the directory:
/usr/local/lib
You need system privileges to do so. In case of an emergency
you may put this file into your home directory, but remember to
ask a system administrator to copy cr_info into /usr/local/lib. Otherwise,
nobody else will be able to run the HKL programs.
|